Premium Plumbing Fixtures
Browse our selection of high-quality products with professional installation services.



Need Professional Installation?
Our certified technicians provide expert installation services for all products.
Contact UsComprehensive Product Specifications
Technical details for informed purchasing decisions
Material Composition & Durability
Our plumbing fixtures utilize advanced material engineering for optimal performance. Toilet bowls are constructed from vitreous china fired at 1250-1300°C, creating a non-porous surface with water absorption rates below 0.5%. Stainless steel sinks feature 18/10 chromium-nickel composition (18% chromium, 10% nickel) for superior corrosion resistance. Brass fittings contain 60-65% copper with precise zinc and tin additives to prevent dezincification.
Shower components employ Type 316 marine-grade stainless steel in high-moisture environments. Polymer-based elements incorporate 30% glass fiber reinforcement, achieving tensile strength of 120-150 MPa. All ceramic disc valves undergo 500,000 cycle testing with less than 0.5% leakage rate. Surface hardness ratings exceed 7 Mohs for porcelain and 5.5 Mohs for composite granite.
Hydraulic Performance Metrics
Water flow dynamics are engineered for maximum efficiency. Standard faucets deliver 2.2-2.5 gpm at 60 psi, while WaterSense models achieve 1.5 gpm without performance compromise. Toilet flush valves feature 1.6" diameter openings generating 25-35 psi flush pressure, moving 350-400 grams of waste per 1.28 gallon flush. Pressure-assisted systems develop 45-55 psi for commercial applications.
Showerheads utilize laminar flow technology providing 2.0 gpm coverage 40% wider than aerated models. Drainage systems maintain optimal 1/4" per foot slope for 1.5" pipes (2% grade), increasing to 1/2" per foot for 3" waste lines. Vent stacks equal largest drain diameter (minimum 1.5") and extend 6" above flood level rim. All DWV systems include cleanouts every 50' and at 90° turns.
Installation Requirements
Precise measurements ensure proper functionality. Standard toilet rough-ins require 12" from wall to drain center (range 10-14"). Vanity heights vary from 32" (children) to 36" (standard) with 21" knee clearance. Shower valves install at 48" height with diverter 12" above tub rim. ADA-compliant fixtures mandate 17-19" toilet seat height and 27" sink clearance.
Pipe support intervals must not exceed 4' for 1/2" copper, 6' for 3/4", and 8' for 1" diameter. Water hammer arrestors install within 6' of quick-closing valves. Expansion tanks require 12" clearance and support for thermal growth. All installations must include accessible shutoff valves within 3' of fixtures and comply with IPC 2021/UPC I-2022 standards.
All specifications conform to international plumbing standards including ASME A112.19.2, NSF/ANSI 61, and EN 997. Performance data based on laboratory testing under controlled conditions. Actual performance may vary based on installation and local water conditions.
Advanced Material Engineering Specifications
Comprehensive technical documentation for plumbing components
Metallic Alloy Composition
Brass fittings utilize C36000 free-cutting brass (60-63% Cu, 2.5-3.7% Pb, balance Zn) for optimal machinability and dezincification resistance. Chrome plating adheres to ASTM B633 Class III standards with minimum 0.3 mil thickness over 0.1 mil nickel undercoating. Stainless steel components employ 316L grade (16-18% Cr, 10-14% Ni, 2-3% Mo) for marine environments, with surface passivation per ASTM A967.
Copper tubing meets ASTM B88 Type L requirements (0.035" wall thickness for 1/2") with phosphorus-deoxidized (C12200) composition. All metallic components undergo 500-hour salt spray testing per ASTM B117 with zero red rust formation. Threaded connections conform to ASME B1.20.1 standards with PTFE tape lubrication.
Polymer Formulations
PEX tubing utilizes cross-linked polyethylene with 85% degree of cross-linking (PEX-b method), meeting ASTM F876/F877 standards with 160psi working pressure at 180°F. PVC components use Type I Grade 1 (ASTM D1784) with cell classification 12454-B. ABS drain components comply with ASTM D2661 with minimum 4,000psi tensile strength.
Rubber gaskets employ EPDM compound (ASTM D2000 BC808) with 70±5 durometer hardness. O-rings use FKM fluorocarbon (ASTM D1418) for chemical resistance. All polymer materials are NSF 61 certified for potable water contact and contain UV stabilizers for above-ground applications.
Ceramic Properties
Vitreous china fixtures are fired at 1250-1300°C (2282-2372°F) achieving water absorption <0.5% per ASTM C373. Glaze composition includes feldspar, quartz, and kaolin with lead-free formulations meeting FDA 21 CFR 177.1630. Surface hardness exceeds 7 Mohs with abrasion resistance >10,000 cycles (EN 997).
Porcelain enamel coatings on steel substrates achieve 5.5-6.5 Mohs hardness with thermal shock resistance of 150°C (270°F) differential. All ceramic components undergo dye penetration testing per ASTM C898 with zero leakage. Gloss retention exceeds 90% after 10,000 cleaning cycles (ASTM D2486).
All material specifications comply with international standards including ISO 9001, ANSI/NSF 61, EN 817, and ASME A112.18.1. Testing performed under controlled laboratory conditions. Actual performance may vary based on installation methods and local water chemistry. Consult technical datasheets for application-specific requirements.
Technical Specifications Compendium
Engineering documentation for plumbing system components
Advanced Material Properties
Vitreous china formulations utilize triaxial compositions of 50% kaolin, 25% quartz, and 25% feldspar fired at 1250-1300°C to achieve water absorption rates below 0.5% (ASTM C373). Glaze compositions maintain lead-free formulations with thermal expansion coefficients between 6.5-7.5 × 10⁻⁶/°C to match body expansion. Stainless steel components employ 316L grade with 16-18% chromium, 10-14% nickel, and 2-3% molybdenum for marine-grade corrosion resistance, demonstrating zero red rust after 1000-hour salt spray testing (ASTM B117).
Brass alloys conform to C36000 specifications (60-63% Cu, 2.5-3.7% Pb) with dezincification resistance per ISO 6509 exceeding 200μm penetration depth after 14-day testing. Polymer components utilize glass-fiber reinforced PPS (polyphenylene sulfide) with 40% filler content, achieving tensile strength of 160MPa and deflection temperature under load of 260°C (ASTM D648). Ceramic disc valves employ 96% alumina substrates with surface roughness (Ra) below 0.2μm, guaranteeing 500,000 cycle durability with less than 0.5% leakage rate.
Fluid Dynamics Analysis
Water flow characteristics are engineered to achieve laminar flow (Reynolds number <2000) at standard residential pressures of 40-60 psi. Toilet flush valves utilize 1.6" diameter openings generating 25-35 psi flush pressure, moving 350-400 grams of waste with 1.28 gallon flush volume (ASME A112.19.14). Drainage systems maintain optimal velocity of 2-4 fps through 1/4" per foot slope for 1.5" pipes, increasing to 1/2" per foot for 3" waste lines to prevent solids deposition (IPC Table 704.1).
Showerheads employ flow restrictors maintaining 2.0 gpm at 80 psi while preserving spray force through 0.2mm diameter nozzles arranged in hexagonal patterns. Pressure-balanced valves maintain ±2°F temperature stability with 10:1 turndown ratio, responding to pressure fluctuations within 0.5 seconds. Vent stack sizing follows 1/4 aggregate cross-sectional area rule (UPC 906.2), with wet-vented fixtures requiring minimum 2" diameter for horizontal branches serving multiple fixtures.
Precision Installation Requirements
Fixture rough-in dimensions maintain strict tolerances: toilet flanges require 12" from finished wall to center (tolerance ±1/2"), with closet bolts aligned within 1/8" of centerline. Supply stops install at 6-10" AFF (above finished floor) with 3/8" compression outlets oriented at 45° from vertical. Shower valves mount at 48" AFF (±1") with diverter controls positioned 12" above tub rim (IPC 417.5). ADA-compliant installations mandate 17-19" toilet seat height (ICC A117.1-2017) and 27" minimum knee clearance under sinks.
Pipe support intervals follow ASTM A53 standards: 1/2" copper every 4', 3/4" every 6', and 1" every 8'. Expansion loops require minimum 24" radius for 1/2" tubing, increasing by 4" per additional 1/4" diameter. Water hammer arrestors install within 6' of quick-closing valves (ASSE 1010) with 1/4" per foot drainage slope toward access points. All solvent-welded joints require 15-second hold time after full insertion (ASTM D2855) with primer application per manufacturer specifications.
All engineering specifications conform to international standards including ASME A112.18.1, NSF/ANSI 61, EN 817, and ISO 3821. Performance data derived from laboratory testing under controlled conditions (20°C water at 3 bar dynamic pressure). Actual field performance may vary based on installation quality, water chemistry, and usage patterns. Consult manufacturer technical bulletins for application-specific requirements.